24/7 Emergency Service in Northern Ohio (888)893-0284 info@econtrol.com

Boilers

Commercial and Industrial Boiler Systems for nearly any application

Boilers come in varied types, designs and sizes.  Let us help you determine the right equipment for your application.

Steam Boilers

Cleaver-Brooks Ohio Special Boiler

The Ohio Special firetube design is unique to the state of Ohio to meet the state regulations. It enables unattended boiler room operation for a unit with less than 360 square feet of heating surface.

The complete boiler package includes the pressure vessel, burner and controls with options for low NOx control.

Size Range: Up to 225 horsepower

Fuels: Oil, gas or combination fired

Design: Dryback or wetback and 2, 3, and 4 pass designs

Pressure: 15, 150, 200, 250 psig

>>  Learn how we help our Ohio customers operate full-sized heating steam boilers without the need for a full-time boiler operator in attendance. Read More >>  

Heating Boilers
Commercial steam boilers

Cleaver-Brooks ClearFire-H (horizontal design)

ClearFire-H steam boilers are quiet, compact and available in ten sizes. They utilize AluFerⓇ tubes with fireside extended heating surface to provide maximum heat transfer. Save on fuel with full burner modulation, high turndown with variable speed motor.

With no dampers or moving linkages, boiler operation is reliable and maintenance is simplified. Cleaver-Brooks stocks many models of ClearFire boilers for quick shipment.

Size range: 10 HP – 80 HP 

Uses: For comfort heat and process applications for schools, commercial buildings, apartments and decentralized facilities. 

Fuels: Natural gas and propane

Pressure: 150 psig (ClearFire-H 15 psig) 

Efficiency: Up to 85% 

Emissions: less than 20 ppm NOx, less than 10% CO

Boilers | Your Northern Ohio’s premier supplier of boiler and burner systems.   For modular steam skid system options click here

Cleaver-Brooks Steam Firetube Boilers

Model CBEX

Using advanced engineering methods, design engineers designed the CBEX to optimize every component of the boiler, including the burner, the furnace, and the tubes, in order to provide optimally balanced heat release zones and minimizing thermal stresses in the boiler. Extended heat transfer tubes only found in EX systems uses Computational Fluid Dynamics (CFD) calculations to optimize the geometry of the tube and increase heat transfer by 85%. The result of the advanced heat transfer design is higher efficiency in a smaller footprint. Reduce fuel use with the optional stack economizer by recovering waste heat from flue gases and using it to preheat boiler feedwater. The LevelMaster low-water cutoff and pump control is the safest control available.

Model CBLE

The CBLE firetube boiler is a complete, single-source package including pressure vessel, integral burner, and controls. Components are designed and manufactured for reliability and long life, maximum safety, ease of maintenance, and the lowest emissions, guaranteed.

Model CBJT

The CBJT is a complete package, including pressure vessel, integral burner, and controls. Engineered by Cleaver-Brooks to be a fully compatible boiler and burner package featuring excellent fuel-to-steam/water efficiency, space savings, and low emissions. It is ruggedly contructed for hot water or low and high-pressure steam applications. For customers who prefer the jet burner design, the CBJT provides the highest value, with a focus on safety, ease of maintenance, lowest emissions and the flexibility to add desired options to further enhance the package.

Model ICB

Integrated package includes pressure vessel, ProFire® packaged jet burner, controls, and the latest advances in combustion technology. Upgrade or retrofit your system with Cleaver-Brooks controls, economizers, water treatment systems, and all the other system components to build a state-of-the-art boiler room of virtually any size and capacity.

Learn More

Size range: 15 – 2,200 HP  

Uses: For reliable response for low/high-pressure process steam/heating loads, multiple fuel firing capability. Applications include indirect heating and process for various campus operations, medical facilities, pharmaceuticals and manufacturing operations.  

Fuels: Natural gas, #2 oil, #6 oil and combination

Pressure: up to 300 psig

Emissions: less than 9 ppm NOx to less than 30 ppm NOx

Cleaver-Brooks Industrial Watertube Boilers

From the Steam-Ready line to custom watertube boilers to OSSG boiler and more, Cleaver-Brooks has extensive experience with large steam boilers – no job is too large.

Every aspect of these industrial watertube systems are designed for maximum efficiency, reliability, low emissions and available shop assembled.

Types: D, A, O and external drum-types

Size range: 10,000 lbs/hr to 500,000 lbs/hr

Uses: Central steam plant and industrial process loads. Typical in hospitals, power and utilities and refineries.

Fuels: Natural gas, #2 and #6 oil, alternative fuels, combination

Pressure: Design pressure up to 1,750 psig

Emissions: Available to less than 7 ppm NOx, ultra-low CO

Cleaver-Brooks Heat Recovery Steam Generators (HRSGs)

HRSGs are state-of-the-art customized, packaged heat-recovery steam generators with gas turbines from 1MW to 95 MW. Applications include heat recovery for turbines, waste heat, incinerators, economizers and air heaters.

These custom solutions are engineered from a single-source to ensure the highest quality output in the 1-15 MW turbine market.

Types: MaxFire, MaxFlow, Slant-VC, Modular, Waste Heat boilers

Size range: 10,000 to 1,000,000 lbs/hr

Uses: Central steam plant, industrial process loads and building heat. Applications include co-gen systems, combined cycle systems, turbine exhaust, gas & diesel engine exhaust, incinerators, and process gas cooling.

Fuels: Natural gas, #2 and #6 oil, alternative fuels, combination

Pressure: Design pressure up to 2,300 psig

Emissions: Available to less than 2 ppm NOx

Cannon Boiler Works
Steam Accumulators

A steam accumulator is a pressure vessel (or tank) with internals and controls, that can reduce the fuel consumption, maintenance costs and increase the service life of your boiler by stabilizing the steam draw conditions, but it cannot make up for shortcomings in total boiler capacity. The accumulator acts as a flywheel or capacitor, storing energy for short periods until the process requires it. 

Large load swings frequently cause boilers to shut down because the system thinks it won’t be able to meet short term steam demands. When this happens, personnel must get involved to rectify the disruption in operations which leads to higher maintenance costs. By incorporating a Steam Accumulator, you can ensure smooth boiler operations with lower maintenance costs.

Learn more about Cannon Steam Accumulators

steam accumulator
steam commercial watertube boiler

Cleaver-Brooks Flexible
Watertube Boilers

Whether stand-alone, or paired with a condensing solution, the FLX model boilers can share the load to increase efficiency in a hydronic or steam process.

The FLX is designed to handle to minimize thermal stress and provide quick response in a compact unit – field erectable units are also an option. it’s easy to incorporate the FLX into a new or existing boiler system.

Size range: 35-600 HP (1,500 – 25,000 MBTU/hr)

Uses: For rapid response for low or high-temperature pressure heating, back up fuel oil and field erectable. Applications include heating for universities, medical facilities, office complexes and process applications such as manufacturing, food processing and pharmaceuticals.

Fuels: #2 fuel oil and gaseous fuels

Pressure: 15 to 150 psig 

Efficiency: Up to 88%

Emissions: Available to <9 ppm

Cleaver-Brooks Steam
Electric Boilers

From the high-voltage CEJS electrode boiler with capacities of up to 188,000 lb/hr down to the vertical and horizontal-type electric boilers with capacities as low as 31 lb/hr.  Cleaver-Brooks electric boilers are clean, compact, quiet, easy to install and have no venting or fuel requirements.

With no combustion considerations, electric boilers are an ideal alternative where emissions regulations are a concern.  The units typically include operating controls, elements, fuses, contactors, safety valve and instrumentation.  

Heating power: 31 lb/hr to 188,000 lb/hr 

Pressure: 15, 150, 200 & 250 PSIG

Uses: High and low pressure steam applications like garment pressing, medical sterilizers, steam rooms, air humidification and more

Warranty: 5 years on the pressure vessel

Commercial Boilers

Boilers | Your Northern Ohio’s premier supplier of boiler and burner systems.   For modular hydronic skid system options click here

Cleaver-Brooks
ClearFire-T (tubeless)

The CBT tubeless vertical boiler provides 99% dry-quality steam – low or high pressure – all delivered in a compact, easy to service versicle design to effectively and reliably meet your steam process requirements. Cleaver-Brooks stocks many models of ClearFire boilers for quick shipment.

Size range: 10 HP – 50 HP

Uses: For comfort heat and process applications for schools, commercial buildings, apartments and decentralized facilities. 

Fuels: Natural gas and propane

Pressure: 15 psig or 150 psig 

Efficiency: Up to 84% and 4:1 turndown

Emissions: Standard burner or Low-emissions premix option

Tubeless boiler

Hydronic Solutions

Cleaver-Brooks, one of the largest boiler manufacturers of packaged boilers, offers a complete line of hot water boiler systems.

System Flexibility 

By focusing on the benefits of integration, Cleaver-Brooks has developed a full range of hydronic solutions that offer the best-in-class quality for performance, efficiency and savings, and the control system to operate any system at peak performance. Choose from condensing, non-condensing or a combination of both to develop a flexible solution specific to your needs

High-Efficiency Condensing Boilers

Condensing

Condensing boiler technology offers boiler efficiencies in the mid-to high-90s. Cleaver-Brooks understands how to leverage your system design and combine it with a coordinated control strategy to squeeze more out of your system’s efficiency.

Non Condensing

Great for systems requiring high operational temperatures or pressures and/or fuel flexibility that preclude the use of condensing technology. Our non-condensing line offers operating efficiencies up to 88% and can be integrated into any system design.

Cleaver-Brooks ClearFire-CE

A compact, fully condensing high-mass hydronic boiler capable of variable-flow pumping, allowing for maximum operating efficiency in a variety of applications. The fireside heating surfaces utilizes industry leading AluFer® tubes for superior efficiencies.

The dual-return connections have the ability to increase condensing in the boiler and raise efficiencies by 6%+ more than a single-return boiler.

Size range: 500 MBTU – 6,000 MBTU

Uses: For comfort heat, schools, hotels, commercial buildings and apartments 

Fuels: Natural gas and propane

Pressure: 125 psi (ClearFire-C/CE or 160 psi (ClearFire-LC)

Efficiency: Up to 99% efficient

Emissions: Standard less than 20 ppm NOx

Warranty: Lifetime warranty on thermal stress!  Optional extended warranties on parts, burner canister and fireside corrosion. 

high efficiency hydronic boiler

Cleaver-Brooks ClearFire-LC

Get maximum flexibility for larger facilities with enhanced efficiency. The larger capacity design allows for few units as opposed to banks of smaller boilers, which reduces capital cost, complexity and maintenance.

Size range: 8,000 MBTU

Uses: For comfort heat, schools, hotels, commercial buildings and apartments 

Fuels: Natural gas and propane

Pressure: 160 psi 

Efficiency: Up to 98% efficient

Emissions: Ultra low emissions

Warranty: 20 years against thermal shock, 10 years pressure vessel

Cleaver-Brooks SwitchFire

Get maximum flexibility for larger facilities with enhanced efficiency. The larger capacity design allows for few units as opposed to banks of smaller boilers, which reduces capital cost, complexity and maintenance.

Size range: 6,000, 10,000, 12,000 MBH capacities 

Uses: For healthcare facilities, building heat, manufacturing processes, colleges/universities 

Fuels: Dual fuel condensing – gas with #2 oil back-up or gas-only condensing

Pressure: 160 psi 

Efficiency: Fully condensing with up to 98% efficiency

Emissions: Standard less than 30 ppm NOx (natural gas), Standard less than 60 ppm NOx (#2 fuel oil)

CleaverBrooks SwitchFire Hydronic Boiler

Cleaver-Brooks Non-Condensing Boilers

commercial watertube boiler

Cleaver-Brooks Flexible Watertube (FLX)

Whether stand-alone or utilized a condensing/non-condensing hybrid multi-unit solution the model FLX boilers can share the load to increase efficiency in a hydronic or steam process.

The FLX is designed to handle to minimize thermal stress and provide quick response in a compact unit – field erectable units are also an option. With no requirement for FGR piping from the stack to burner, it’s easy to incorporate the FLX into a new or existing boiler system.

Size range: 1,500 – 25,000 MBTU/hr (35-600 HP)

Uses: For rapid response for low or high-temperature pressure heating, back up fuel oil and field erectable. Applications include heating for universities, medical facilities, office complexes and process applications such as manufacturing, food processing and pharmaceuticals.

Fuels: #2 fuel oil and gaseous fuels

Pressure: 160 psig 

Efficiency: Up to 88%

Emissions: Available to < 9 ppm

Cleaver-Brooks Firetube
Hot Water Boilers

Model CBEX

Using advanced engineering methods, design engineers designed the CBEX to optimize every component of the boiler, including the burner, the furnace, and the tubes, in order to provide optimally balanced heat release zones and minimizing thermal stresses in the boiler. Extended heat transfer tubes only found in EX systems uses Computational Fluid Dynamics (CFD) calculations to optimize the geometry of the tube and increase heat transfer by 85%. The result of the advanced heat transfer design is higher efficiency in a smaller footprint. Reduce fuel use with the optional stack economizer by recovering waste heat from flue gases and using it to preheat boiler feedwater. The LevelMaster low-water cutoff and pump control is the safest control available.

Model CBLE

The CBLE firetube boiler is a complete, single-source package including pressure vessel, integral burner, and controls. Components are designed and manufactured for reliability and long life, maximum safety, ease of maintenance, and the lowest emissions, guaranteed. 

Model CBJT

The CBJT is a complete package, including pressure vessel, integral burner, and controls. Engineered by Cleaver-Brooks to be a fully compatible boiler and burner package featuring excellent fuel-to-steam/water efficiency, space savings, and low emissions. It is ruggedly contructed for hot water or low and high-pressure steam applications. For customers who prefer the jet burner design, the CBJT provides the highest value, with a focus on safety, ease of maintenance, lowest emissions and the flexibility to add desired options to further enhance the package. 

Learn More

Size Range: 15 – 2,200 HP

Uses: For reliable response for low/high-temperature pressure heating, multiple fuel firing. Applications include heating for universities, medical facilities, office complexes and process applications such as manufacturing, food processing and pharmaceuticals.

Fuels: Natural gas, #2 oil, #6 oil and combination

Pressure: 30 to 125 psig

Emissions: < 9 ppm NOx to <30 ppm NOx

Electric Boiler

Cleaver-Brooks Hot
Water Electric Boilers

For commercial and industrial applications, Cleaver-Brooks steam electric boilers are clean, compact, quiet, easy to install and have no venting or fuel requirements. With no combustion considerations, electric boilers are a good alternative where emissions regulations are a concern.

The units typically include operating controls, elements, fuses, contactors, safety valve and instrumentation.

Hydronic

Heating power: 12 kW to 3360 kW 

Pressure: 160, 200 and 250 PSIG

Uses: Comfort heating

Warranty: 5 years on the pressure vessel

Skid Systems

Skid mounted hydronic boiler system

Cleaver-Brooks Packaged
Skid Systems

Pre-engineered for steam or hot water applications, Cleaver-Brooks skid-mounted boiler packages come pre-piped with electrical connections for simple and easy field installation.

Various boiler designs are available in standard packages or create a custom package with the number of boilers, pumps and accessories.

Hydronic Skid-Mounted System

Size Range: 500 to 12,000 MBH

Fuels: Natural gas/propane or dual fuel (depending on model)

Uses: This modular solution is ideal for office buildings, medical buildings, schools, industrial process, heating and process applications. 

Pressure(s): 5-150 psig

Skid mounted steam boiler system

Steam Skid-Mounted System

Size range: 9.5 – 60 HP

Fuels: Natural gas/propane or dual fuel (depending on model)

Uses: This modular solution is ideal for office buildings, medical buildings, schools, industrial process, heating and process applications. 

Pressure(s): Up to 500 psig